Miscellaneous Equipment > Testing, Inspection & Measuring > Environmental Chambers    < Back

Sub-Zero ZP-32 Environmental Chamber, Cincinnati ZPHS-32-1.5-H Freezer - $14,900

Item Number: #00099981
Sub-Zero ZP-32 Environmental Chamber, Cincinnati ZPHS-32-1.5-H Freezer

Sub-Zero ZP-32 Environmental Chamber, Cincinnati ZPHS-32-1.5-H Freezer
Price: $14,900

Environmental Chambers

Chamber width38"
Chamber length38"
Year of Manufacture:  2009 (estimated)
Manufacturer:  Cincinnati
Model:  ZPHS-32-1.5-H
Condition: Used
Cincinnati Sub-Zero Temperature Humidity Test Chamber – Model ZPH-32-1.5-H/AC

Temperature Range: -34°C (-30°F) to +190°C (+375°F)

Humidity Range: 10% to 98% relative humidity as limited by a +85°C (+185°F) maximum dry bulb and a +7°C (+45°F) minimum dew point.

Control Stability: ±0.5°C (+1°F); ±3% relative humidity at steady state conditions after stabilization

Temperature Performance: The ZPH-32-1.5-H/AC will cycle between +85°C (+185°F) and
(Non-humidity operation) -20°C (-4°F) at an average temperature change rate of 2°C per minute based on an empty chamber.

Temperature pull down from +24°C (+75°F) to:
-18°C ( 0°F) in 20 minutes
-34°C (-30°F) in 55 minutes

Temperature heat-up from:
+24°C (+75°F) to + 94°C (+200°F) in 20 minutes
+24°C (+75°F) to +190°C (+375°F) in 60 minutes
-34°C (-30°F) to + 24°C (+ 75°F) in 10 minutes

(Based on +24C/+75F ambient, 230 volt service,
and use of included accessories. Some accessories
may affect performance.)

Live Load Capacity: 1,200 watts at -18°C ( 0°C)
250 watts at -34°C (-30°F)
Note: Humidity control will be affected by the addition of live load.

Workspace Volume: 32 Cubic Feet (905 Liters)

Interior Dimensions: 38" wide x 38" deep x 38" high
(97cm wide x 97 cm deep x 97 cm high)

Exterior Dimensions: 46" wide x 83.75" deep x 89.50" high
(117 cm wide x 213 cm deep x 227 cm high)
(Addition of certain accessories may increase dimensions.)

Shipping Weight: Approximately 2,075 pounds

Utility Requirements: 208 or 230 volt (±5%), 60 hertz
- 1 phase, 28 FLA, 35 amp minimum service
- 3 phase, 26 FLA, 35 amp minimum service
(Customer to provide power cord and plug)

Heat Rejection: Approximately 6,400 watts (22,000 BTU/hr) maximum during cooling operation.

Air Flow
This machine is listed for sale by Myers Technology, LLC. located in Elk Grove Village, Illinois
Contact the Seller
Myers Technology, LLC.
  2150 Touhy Ave.
Elk Grove Village
IL 60007
United States
Request Call from Seller Email seller
View sellers full listings/Website

Email Seller

Type the code shown*:
Security Code
Send Email
* Mandatory field
Note: For security all enquiries may be monitored

Print Advert Tell a Friend
Add to Watch List Report Advert
* Report advert as sold or incorrect details